Study on the Possible Error Due to Matrix Interaction in Automated SEM/EDS Analysis of Nonmetallic Inclusions in Steel by Thermodynamics, Kinetics and Electrolytic Extraction

Research output: Contribution to journalArticleResearchpeer-review

Bibtex - Download

@article{0fd0b78d75424a2e9e0f0d4c628226ad,
title = "Study on the Possible Error Due to Matrix Interaction in Automated SEM/EDS Analysis of Nonmetallic Inclusions in Steel by Thermodynamics, Kinetics and Electrolytic Extraction",
abstract = "Up to now, the Fe content of nonmetallic particles has often been neglected in chemical evaluations due to the challenging analysis of matrix elements in nonmetallic inclusions (NMI) in steel by scanning electron microscope and energy dispersive spectroscopy analysis (SEM/EDS). Neglecting matrix elements as possible bonding partners of forming particles may lead to inaccurate results. In the present study, a referencing method for the iron content in nonmetallic inclusions in the submicrometer region is described focusing on the system Fe-Mn-O. Thermodynamic and kinetic calculations are applied to predict the inclusion population for different Fe/Mn ratios. Reference samples containing (Fe,Mn)-oxide inclusions with varying Fe ratios are produced by manganese deoxidation in a high-frequency induction furnace. Subsequent SEM/EDS measurements are performed on metallographic specimens and electrolytically extracted nonmetallic inclusions down to 0.3 µm. The limits of iron detection in these particles, especially for those in the submicrometric regime, as well as the possible influence of electrolytic extraction on Fe-containing oxide particles are examined. The measured inclusion compositions correlate well with the calculated results regarding segregation and kinetics. The examinations performed are reliable proof for the application of SEM/EDS measurements to evaluate the Fe content in nonmetallic inclusions, within the physical limits of polished cross-section samples. Only electrolytic extraction ensures the determination of accurate compositions of dissolved or bonded matrix elements at smallest particles enabling quantitative particle descriptions for submicrometric (particles ≤ 1 µm) steel cleanness evaluations.",
keywords = "nonmetallic inclusion, automated/manual SEM/EDS, electrolytic extraction, Thermodynamic and kinetic simulation, Fe-containing particles, matrix interaction, reference measurements, submicro steel cleanness, (Fe,Mn)oxides",
author = "Alexander Mayerhofer and Dali You and Peter Presoly and Christian Bernhard and Michelic, {Susanne Katharina}",
year = "2020",
month = jun,
day = "29",
doi = "10.3390/met10070860",
language = "English",
volume = "10.2020",
pages = "1--16",
journal = "Metals : open access journal ",
issn = "2075-4701",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "7",

}

RIS (suitable for import to EndNote) - Download

TY - JOUR

T1 - Study on the Possible Error Due to Matrix Interaction in Automated SEM/EDS Analysis of Nonmetallic Inclusions in Steel by Thermodynamics, Kinetics and Electrolytic Extraction

AU - Mayerhofer, Alexander

AU - You, Dali

AU - Presoly, Peter

AU - Bernhard, Christian

AU - Michelic, Susanne Katharina

PY - 2020/6/29

Y1 - 2020/6/29

N2 - Up to now, the Fe content of nonmetallic particles has often been neglected in chemical evaluations due to the challenging analysis of matrix elements in nonmetallic inclusions (NMI) in steel by scanning electron microscope and energy dispersive spectroscopy analysis (SEM/EDS). Neglecting matrix elements as possible bonding partners of forming particles may lead to inaccurate results. In the present study, a referencing method for the iron content in nonmetallic inclusions in the submicrometer region is described focusing on the system Fe-Mn-O. Thermodynamic and kinetic calculations are applied to predict the inclusion population for different Fe/Mn ratios. Reference samples containing (Fe,Mn)-oxide inclusions with varying Fe ratios are produced by manganese deoxidation in a high-frequency induction furnace. Subsequent SEM/EDS measurements are performed on metallographic specimens and electrolytically extracted nonmetallic inclusions down to 0.3 µm. The limits of iron detection in these particles, especially for those in the submicrometric regime, as well as the possible influence of electrolytic extraction on Fe-containing oxide particles are examined. The measured inclusion compositions correlate well with the calculated results regarding segregation and kinetics. The examinations performed are reliable proof for the application of SEM/EDS measurements to evaluate the Fe content in nonmetallic inclusions, within the physical limits of polished cross-section samples. Only electrolytic extraction ensures the determination of accurate compositions of dissolved or bonded matrix elements at smallest particles enabling quantitative particle descriptions for submicrometric (particles ≤ 1 µm) steel cleanness evaluations.

AB - Up to now, the Fe content of nonmetallic particles has often been neglected in chemical evaluations due to the challenging analysis of matrix elements in nonmetallic inclusions (NMI) in steel by scanning electron microscope and energy dispersive spectroscopy analysis (SEM/EDS). Neglecting matrix elements as possible bonding partners of forming particles may lead to inaccurate results. In the present study, a referencing method for the iron content in nonmetallic inclusions in the submicrometer region is described focusing on the system Fe-Mn-O. Thermodynamic and kinetic calculations are applied to predict the inclusion population for different Fe/Mn ratios. Reference samples containing (Fe,Mn)-oxide inclusions with varying Fe ratios are produced by manganese deoxidation in a high-frequency induction furnace. Subsequent SEM/EDS measurements are performed on metallographic specimens and electrolytically extracted nonmetallic inclusions down to 0.3 µm. The limits of iron detection in these particles, especially for those in the submicrometric regime, as well as the possible influence of electrolytic extraction on Fe-containing oxide particles are examined. The measured inclusion compositions correlate well with the calculated results regarding segregation and kinetics. The examinations performed are reliable proof for the application of SEM/EDS measurements to evaluate the Fe content in nonmetallic inclusions, within the physical limits of polished cross-section samples. Only electrolytic extraction ensures the determination of accurate compositions of dissolved or bonded matrix elements at smallest particles enabling quantitative particle descriptions for submicrometric (particles ≤ 1 µm) steel cleanness evaluations.

KW - nonmetallic inclusion

KW - automated/manual SEM/EDS

KW - electrolytic extraction

KW - Thermodynamic and kinetic simulation

KW - Fe-containing particles

KW - matrix interaction

KW - reference measurements

KW - submicro steel cleanness

KW - (Fe,Mn)oxides

UR - http://www.scopus.com/inward/record.url?scp=85087135651&partnerID=8YFLogxK

U2 - 10.3390/met10070860

DO - 10.3390/met10070860

M3 - Article

VL - 10.2020

SP - 1

EP - 16

JO - Metals : open access journal

JF - Metals : open access journal

SN - 2075-4701

IS - 7

M1 - 860

ER -