Fast differential scanning calorimetry to mimic additive manufacturing processing: specific heat capacity analysis of aluminium alloys
Research output: Contribution to journal › Article › Research › peer-review
Standard
In: Journal of Thermal Analysis and Calorimetry, Vol. 148.2023, No. February, 2022, p. 651-662.
Research output: Contribution to journal › Article › Research › peer-review
Harvard
APA
Vancouver
Author
Bibtex - Download
}
RIS (suitable for import to EndNote) - Download
TY - JOUR
T1 - Fast differential scanning calorimetry to mimic additive manufacturing processing
T2 - specific heat capacity analysis of aluminium alloys
AU - Quick, Cameron R.
AU - Dumitraschkewitz, Phillip
AU - Schawe, Jürgen E. K.
AU - Pogatscher, Stefan
N1 - Publisher Copyright: © 2022, The Author(s).
PY - 2022
Y1 - 2022
N2 - Eutectic AlSi12, commonly used in casting and in additive manufacturing, is investigated with Fast Differential Scanning Calorimetry to determine the impact of different cooling rates from the liquid state upon the apparent specific heat capacity on subsequent heating. A heat flow correction strategy is developed and refined for the reliable and precise measurement of sample heat flow using chip sensors and assessed by the evaluation of results on pure (99.999%) aluminium. That strategy is then applied to the study of the AlSi12 eutectic alloy, and rate-dependent perturbations in the measured apparent specific heat capacity are discussed in terms of Si supersaturation and precipitation. Several cooling rates were implemented from − 100 to − 30,000 K s−1, and subsequent heating ranged from + 1000 to + 30,000 K s−1. After rapid cooling, a drop in AlSi12 apparent specific heat capacity is found on heating above ~ 400 °C; even at rates of + 10,000 K s−1, a result which has high relevance in metal additive manufacturing where similarly fast temperature cycles are involved. The Literature data, temperature modulated DSC and CALPHAD simulations on the heat capacity of AlSi12 are used to provide comparative context to the results from Fast Differential Scanning Calorimetry.
AB - Eutectic AlSi12, commonly used in casting and in additive manufacturing, is investigated with Fast Differential Scanning Calorimetry to determine the impact of different cooling rates from the liquid state upon the apparent specific heat capacity on subsequent heating. A heat flow correction strategy is developed and refined for the reliable and precise measurement of sample heat flow using chip sensors and assessed by the evaluation of results on pure (99.999%) aluminium. That strategy is then applied to the study of the AlSi12 eutectic alloy, and rate-dependent perturbations in the measured apparent specific heat capacity are discussed in terms of Si supersaturation and precipitation. Several cooling rates were implemented from − 100 to − 30,000 K s−1, and subsequent heating ranged from + 1000 to + 30,000 K s−1. After rapid cooling, a drop in AlSi12 apparent specific heat capacity is found on heating above ~ 400 °C; even at rates of + 10,000 K s−1, a result which has high relevance in metal additive manufacturing where similarly fast temperature cycles are involved. The Literature data, temperature modulated DSC and CALPHAD simulations on the heat capacity of AlSi12 are used to provide comparative context to the results from Fast Differential Scanning Calorimetry.
KW - Additive manufacturing (AM)
KW - Aluminium alloys
KW - Fast differential scanning calorimetry (FDSC)
KW - Precipitation
KW - Specific heat capacity
UR - http://www.scopus.com/inward/record.url?scp=85143516358&partnerID=8YFLogxK
U2 - 10.1007/s10973-022-11824-4
DO - 10.1007/s10973-022-11824-4
M3 - Article
AN - SCOPUS:85143516358
VL - 148.2023
SP - 651
EP - 662
JO - Journal of Thermal Analysis and Calorimetry
JF - Journal of Thermal Analysis and Calorimetry
SN - 1388-6150
IS - February
ER -