Fast differential scanning calorimetry to mimic additive manufacturing processing: specific heat capacity analysis of aluminium alloys

Research output: Contribution to journalArticleResearchpeer-review

Standard

Fast differential scanning calorimetry to mimic additive manufacturing processing: specific heat capacity analysis of aluminium alloys. / Quick, Cameron R.; Dumitraschkewitz, Phillip; Schawe, Jürgen E. K. et al.
In: Journal of Thermal Analysis and Calorimetry, Vol. 148.2023, No. February, 2022, p. 651-662.

Research output: Contribution to journalArticleResearchpeer-review

Bibtex - Download

@article{04bf9b60a5ea4261927580ce6a0ca193,
title = "Fast differential scanning calorimetry to mimic additive manufacturing processing: specific heat capacity analysis of aluminium alloys",
abstract = "Eutectic AlSi12, commonly used in casting and in additive manufacturing, is investigated with Fast Differential Scanning Calorimetry to determine the impact of different cooling rates from the liquid state upon the apparent specific heat capacity on subsequent heating. A heat flow correction strategy is developed and refined for the reliable and precise measurement of sample heat flow using chip sensors and assessed by the evaluation of results on pure (99.999%) aluminium. That strategy is then applied to the study of the AlSi12 eutectic alloy, and rate-dependent perturbations in the measured apparent specific heat capacity are discussed in terms of Si supersaturation and precipitation. Several cooling rates were implemented from − 100 to − 30,000 K s−1, and subsequent heating ranged from + 1000 to + 30,000 K s−1. After rapid cooling, a drop in AlSi12 apparent specific heat capacity is found on heating above ~ 400 °C; even at rates of + 10,000 K s−1, a result which has high relevance in metal additive manufacturing where similarly fast temperature cycles are involved. The Literature data, temperature modulated DSC and CALPHAD simulations on the heat capacity of AlSi12 are used to provide comparative context to the results from Fast Differential Scanning Calorimetry.",
keywords = "Additive manufacturing (AM), Aluminium alloys, Fast differential scanning calorimetry (FDSC), Precipitation, Specific heat capacity",
author = "Quick, {Cameron R.} and Phillip Dumitraschkewitz and Schawe, {J{\"u}rgen E. K.} and Stefan Pogatscher",
note = "Publisher Copyright: {\textcopyright} 2022, The Author(s).",
year = "2022",
doi = "10.1007/s10973-022-11824-4",
language = "English",
volume = "148.2023",
pages = "651--662",
journal = "Journal of Thermal Analysis and Calorimetry",
issn = "1388-6150",
publisher = "Springer Netherlands",
number = "February",

}

RIS (suitable for import to EndNote) - Download

TY - JOUR

T1 - Fast differential scanning calorimetry to mimic additive manufacturing processing

T2 - specific heat capacity analysis of aluminium alloys

AU - Quick, Cameron R.

AU - Dumitraschkewitz, Phillip

AU - Schawe, Jürgen E. K.

AU - Pogatscher, Stefan

N1 - Publisher Copyright: © 2022, The Author(s).

PY - 2022

Y1 - 2022

N2 - Eutectic AlSi12, commonly used in casting and in additive manufacturing, is investigated with Fast Differential Scanning Calorimetry to determine the impact of different cooling rates from the liquid state upon the apparent specific heat capacity on subsequent heating. A heat flow correction strategy is developed and refined for the reliable and precise measurement of sample heat flow using chip sensors and assessed by the evaluation of results on pure (99.999%) aluminium. That strategy is then applied to the study of the AlSi12 eutectic alloy, and rate-dependent perturbations in the measured apparent specific heat capacity are discussed in terms of Si supersaturation and precipitation. Several cooling rates were implemented from − 100 to − 30,000 K s−1, and subsequent heating ranged from + 1000 to + 30,000 K s−1. After rapid cooling, a drop in AlSi12 apparent specific heat capacity is found on heating above ~ 400 °C; even at rates of + 10,000 K s−1, a result which has high relevance in metal additive manufacturing where similarly fast temperature cycles are involved. The Literature data, temperature modulated DSC and CALPHAD simulations on the heat capacity of AlSi12 are used to provide comparative context to the results from Fast Differential Scanning Calorimetry.

AB - Eutectic AlSi12, commonly used in casting and in additive manufacturing, is investigated with Fast Differential Scanning Calorimetry to determine the impact of different cooling rates from the liquid state upon the apparent specific heat capacity on subsequent heating. A heat flow correction strategy is developed and refined for the reliable and precise measurement of sample heat flow using chip sensors and assessed by the evaluation of results on pure (99.999%) aluminium. That strategy is then applied to the study of the AlSi12 eutectic alloy, and rate-dependent perturbations in the measured apparent specific heat capacity are discussed in terms of Si supersaturation and precipitation. Several cooling rates were implemented from − 100 to − 30,000 K s−1, and subsequent heating ranged from + 1000 to + 30,000 K s−1. After rapid cooling, a drop in AlSi12 apparent specific heat capacity is found on heating above ~ 400 °C; even at rates of + 10,000 K s−1, a result which has high relevance in metal additive manufacturing where similarly fast temperature cycles are involved. The Literature data, temperature modulated DSC and CALPHAD simulations on the heat capacity of AlSi12 are used to provide comparative context to the results from Fast Differential Scanning Calorimetry.

KW - Additive manufacturing (AM)

KW - Aluminium alloys

KW - Fast differential scanning calorimetry (FDSC)

KW - Precipitation

KW - Specific heat capacity

UR - http://www.scopus.com/inward/record.url?scp=85143516358&partnerID=8YFLogxK

U2 - 10.1007/s10973-022-11824-4

DO - 10.1007/s10973-022-11824-4

M3 - Article

AN - SCOPUS:85143516358

VL - 148.2023

SP - 651

EP - 662

JO - Journal of Thermal Analysis and Calorimetry

JF - Journal of Thermal Analysis and Calorimetry

SN - 1388-6150

IS - February

ER -