Evaluation of Performance of an Amine Based and an Imidazoline Based Gas Condensate Inhibitor Tested with a High Velocity Laboratory Test Rig
Research output: Contribution to journal › Article › Research › peer-review
Standard
In: Berg- und hüttenmännische Monatshefte : BHM, Vol. 160.2015, No. 7, 02.07.2015, p. 346-351.
Research output: Contribution to journal › Article › Research › peer-review
Harvard
APA
Vancouver
Author
Bibtex - Download
}
RIS (suitable for import to EndNote) - Download
TY - JOUR
T1 - Evaluation of Performance of an Amine Based and an Imidazoline Based Gas Condensate Inhibitor Tested with a High Velocity Laboratory Test Rig
AU - Prethaler, Andreas
AU - Mori, Gregor
AU - Rosenberg, Erwin
PY - 2015/7/2
Y1 - 2015/7/2
N2 - An amine based CO2 corrosion inhibitor and an imidazoline based CO2 corrosion inhibitor have been tested in a two-phase laboratory flow loop system under conditions of a gas condensate well in Austria. After a detailed description of the experimental setups, degradation rates of material API L-80 (UNS G41300) as function of flow velocity and inhibitor dosage are presented. Further, the influence of chloride addition on inhibitor performance has been investigated. All results are discussed with respect to critical inhibitor concentration to reach nearly 100 % inhibitor efficiency.Inhibitor A exhibits alkylamine as an active ingredient dissolved in ethylene glycol and different alcohols, and the effect of inhibitor B is based on imidazoline dissolved in different alcohols. Results demonstrate that the test rig delivers reasonable results with respect to inhibitor protection rates. Independent of superficial flow velocities (tested between 3 and 35 m/s), both inhibitors exhibit a good performance as long as dosed above their critical concentration. The critical concentration is clearly below 100 ppm to the liquid phase. The addition of chlorides affects the performance of the alkylamine based inhibitor significantly more than in case of the imidazoline.
AB - An amine based CO2 corrosion inhibitor and an imidazoline based CO2 corrosion inhibitor have been tested in a two-phase laboratory flow loop system under conditions of a gas condensate well in Austria. After a detailed description of the experimental setups, degradation rates of material API L-80 (UNS G41300) as function of flow velocity and inhibitor dosage are presented. Further, the influence of chloride addition on inhibitor performance has been investigated. All results are discussed with respect to critical inhibitor concentration to reach nearly 100 % inhibitor efficiency.Inhibitor A exhibits alkylamine as an active ingredient dissolved in ethylene glycol and different alcohols, and the effect of inhibitor B is based on imidazoline dissolved in different alcohols. Results demonstrate that the test rig delivers reasonable results with respect to inhibitor protection rates. Independent of superficial flow velocities (tested between 3 and 35 m/s), both inhibitors exhibit a good performance as long as dosed above their critical concentration. The critical concentration is clearly below 100 ppm to the liquid phase. The addition of chlorides affects the performance of the alkylamine based inhibitor significantly more than in case of the imidazoline.
U2 - 10.1007/s00501-015-0387-9
DO - 10.1007/s00501-015-0387-9
M3 - Article
VL - 160.2015
SP - 346
EP - 351
JO - Berg- und hüttenmännische Monatshefte : BHM
JF - Berg- und hüttenmännische Monatshefte : BHM
SN - 0005-8912
IS - 7
ER -