Improvement and presentation of two novel, innovative filter testing methods
Publikationen: Thesis / Studienabschlussarbeiten und Habilitationsschriften › Masterarbeit
Standard
2010.
Publikationen: Thesis / Studienabschlussarbeiten und Habilitationsschriften › Masterarbeit
Harvard
Vancouver
Author
Bibtex - Download
}
RIS (suitable for import to EndNote) - Download
TY - THES
T1 - Improvement and presentation of two novel, innovative filter testing methods
AU - Reiss, Georg
N1 - embargoed until null
PY - 2010
Y1 - 2010
N2 - Filter testing methods are described by various industrial standards. A broad range of different parameters, which can be evaluated, are stated there. Nevertheless, many filter testing methods are complicated and time consuming. Two novel filter testing methods are developed in corporation with the company ICE Strömungsforschung GmbH. The first method, called translucency examination, makes it possible to find out a direct correlation between the pressure drop of filter samples and their local grey values, determined by photography. Furthermore, the deviation of the experimental results diminishes because representative samples can be selected. This yields in a reduced working time as fewer samples are needed to get results with an equally sufficient statistical accuracy. The acquisition costs for the translucency examination are relatively low, the handling is simple and it can be integrated into every standardized laboratory procedure without any problems. The second innovative filter testing method is capable of determining the particle penetration depth in filter media with the help of fluorescence macrophotography.
AB - Filter testing methods are described by various industrial standards. A broad range of different parameters, which can be evaluated, are stated there. Nevertheless, many filter testing methods are complicated and time consuming. Two novel filter testing methods are developed in corporation with the company ICE Strömungsforschung GmbH. The first method, called translucency examination, makes it possible to find out a direct correlation between the pressure drop of filter samples and their local grey values, determined by photography. Furthermore, the deviation of the experimental results diminishes because representative samples can be selected. This yields in a reduced working time as fewer samples are needed to get results with an equally sufficient statistical accuracy. The acquisition costs for the translucency examination are relatively low, the handling is simple and it can be integrated into every standardized laboratory procedure without any problems. The second innovative filter testing method is capable of determining the particle penetration depth in filter media with the help of fluorescence macrophotography.
KW - Druckverlustbestimmung
KW - Grauwertbestimmung
KW - Durchlichtverfahren
KW - Partikeleindringtiefe
KW - Partikeltiefenverteilung
KW - Fluoreszenz-Makrofotographie
KW - pressure drop
KW - correlation grey values
KW - translucency examination
KW - particle penetration depth
KW - 3-D particle distribution
M3 - Master's Thesis
ER -