Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr

Publikationen: Beitrag in FachzeitschriftÜbersichtsartikel(peer-reviewed)

Standard

Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr. / Horsky, Monika; Irrgeher, Johanna; Prohaska, Thomas.
in: Analytical and bioanalytical chemistry, Jahrgang 408.2016, Nr. 2, 01.2016, S. 351-367.

Publikationen: Beitrag in FachzeitschriftÜbersichtsartikel(peer-reviewed)

Bibtex - Download

@article{0255da538453421da727139ede918817,
title = "Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr",
abstract = "This paper critically reviews the state-of-the-art of isotope amount ratio measurements by solution-based multi-collector inductively coupled plasma mass spectrometry (MC ICP-MS) and presents guidelines for corresponding data reduction strategies and uncertainty assessments based on the example of n(87Sr)/n(86Sr) isotope ratios. This ratio shows variation attributable to natural radiogenic processes and mass-dependent fractionation. The applied calibration strategies can display these differences. In addition, a proper statement of uncertainty of measurement, including all relevant influence quantities, is a metrological prerequisite. A detailed instructive procedure for the calculation of combined uncertainties is presented for Sr isotope amount ratios using three different strategies of correction for instrumental isotopic fractionation (IIF): traditional internal correction, standard-sample bracketing, and a combination of both, using Zr as internal standard. Uncertainties are quantified by means of a Kragten spreadsheet approach, including the consideration of correlations between individual input parameters to the model equation. The resulting uncertainties are compared with uncertainties obtained from the partial derivatives approach and Monte Carlo propagation of distributions. We obtain relative expanded uncertainties (U rel; k = 2) of n(87Sr)/n(86Sr) of < 0.03 %, when normalization values are not propagated. A comprehensive propagation, including certified values and the internal normalization ratio in nature, increases relative expanded uncertainties by about factor two and the correction for IIF becomes the major contributor.",
keywords = "Uncertainty of measurement, Isotope amount ratio, Strontium isotopes, MCICP-MS, Instrumental isotopic fractionation",
author = "Monika Horsky and Johanna Irrgeher and Thomas Prohaska",
year = "2016",
month = jan,
doi = "10.1007/s00216-015-9003-9",
language = "English",
volume = "408.2016",
pages = "351--367",
journal = "Analytical and bioanalytical chemistry",
issn = "1618-2642",
publisher = "Springer Berlin",
number = "2",

}

RIS (suitable for import to EndNote) - Download

TY - JOUR

T1 - Evaluation strategies and uncertainty calculation of isotope amount ratios measured by MC ICP-MS on the example of Sr

AU - Horsky, Monika

AU - Irrgeher, Johanna

AU - Prohaska, Thomas

PY - 2016/1

Y1 - 2016/1

N2 - This paper critically reviews the state-of-the-art of isotope amount ratio measurements by solution-based multi-collector inductively coupled plasma mass spectrometry (MC ICP-MS) and presents guidelines for corresponding data reduction strategies and uncertainty assessments based on the example of n(87Sr)/n(86Sr) isotope ratios. This ratio shows variation attributable to natural radiogenic processes and mass-dependent fractionation. The applied calibration strategies can display these differences. In addition, a proper statement of uncertainty of measurement, including all relevant influence quantities, is a metrological prerequisite. A detailed instructive procedure for the calculation of combined uncertainties is presented for Sr isotope amount ratios using three different strategies of correction for instrumental isotopic fractionation (IIF): traditional internal correction, standard-sample bracketing, and a combination of both, using Zr as internal standard. Uncertainties are quantified by means of a Kragten spreadsheet approach, including the consideration of correlations between individual input parameters to the model equation. The resulting uncertainties are compared with uncertainties obtained from the partial derivatives approach and Monte Carlo propagation of distributions. We obtain relative expanded uncertainties (U rel; k = 2) of n(87Sr)/n(86Sr) of < 0.03 %, when normalization values are not propagated. A comprehensive propagation, including certified values and the internal normalization ratio in nature, increases relative expanded uncertainties by about factor two and the correction for IIF becomes the major contributor.

AB - This paper critically reviews the state-of-the-art of isotope amount ratio measurements by solution-based multi-collector inductively coupled plasma mass spectrometry (MC ICP-MS) and presents guidelines for corresponding data reduction strategies and uncertainty assessments based on the example of n(87Sr)/n(86Sr) isotope ratios. This ratio shows variation attributable to natural radiogenic processes and mass-dependent fractionation. The applied calibration strategies can display these differences. In addition, a proper statement of uncertainty of measurement, including all relevant influence quantities, is a metrological prerequisite. A detailed instructive procedure for the calculation of combined uncertainties is presented for Sr isotope amount ratios using three different strategies of correction for instrumental isotopic fractionation (IIF): traditional internal correction, standard-sample bracketing, and a combination of both, using Zr as internal standard. Uncertainties are quantified by means of a Kragten spreadsheet approach, including the consideration of correlations between individual input parameters to the model equation. The resulting uncertainties are compared with uncertainties obtained from the partial derivatives approach and Monte Carlo propagation of distributions. We obtain relative expanded uncertainties (U rel; k = 2) of n(87Sr)/n(86Sr) of < 0.03 %, when normalization values are not propagated. A comprehensive propagation, including certified values and the internal normalization ratio in nature, increases relative expanded uncertainties by about factor two and the correction for IIF becomes the major contributor.

KW - Uncertainty of measurement

KW - Isotope amount ratio

KW - Strontium isotopes

KW - MCICP-MS

KW - Instrumental isotopic fractionation

U2 - 10.1007/s00216-015-9003-9

DO - 10.1007/s00216-015-9003-9

M3 - Review article

VL - 408.2016

SP - 351

EP - 367

JO - Analytical and bioanalytical chemistry

JF - Analytical and bioanalytical chemistry

SN - 1618-2642

IS - 2

ER -