Effect of compressibility on industrial DC electric arcs

Publikationen: Beitrag in FachzeitschriftArtikelForschung(peer-reviewed)

Standard

Effect of compressibility on industrial DC electric arcs. / Al Nasser, Mohamad; Barati, Hadi; Redl, Christian et al.
in: Results in Engineering, Jahrgang 19.2023, Nr. September, 101312, 22.07.2023.

Publikationen: Beitrag in FachzeitschriftArtikelForschung(peer-reviewed)

Vancouver

Al Nasser M, Barati H, Redl C, Ishmurzin A, Voller N, Hackl G et al. Effect of compressibility on industrial DC electric arcs. Results in Engineering. 2023 Jul 22;19.2023(September):101312. doi: 10.1016/j.rineng.2023.101312

Author

Al Nasser, Mohamad ; Barati, Hadi ; Redl, Christian et al. / Effect of compressibility on industrial DC electric arcs. in: Results in Engineering. 2023 ; Jahrgang 19.2023, Nr. September.

Bibtex - Download

@article{acffb6186818474c8ba7bcf1e95882e4,
title = "Effect of compressibility on industrial DC electric arcs",
abstract = "The paper reports on the behaviour and dynamics of direct current electric arc in an industrial electric arc furnace. Electric arcs are intense energy sources involved in many industrial processes. The behaviour of electric arc is simulated in a 2D axisymmetric geometry. A 40 kA current flows between two electrodes with a gap of 0.25 cm. The flow of current creates a very powerful jet up to km/s. Such speeds pose the question of the importance of compressibility and what is the extent of the effects of compressibility on arc behaviour. To assess the effect of compressibility, two different simulations are performed: an incompressible and a compressible simulation. The first simulation considers a temperature-dependent density based on experimental measurement whereas the latter adopts the ideal gas law to calculate the density variation of the plasma. The incompressible results were previously validated and compared to the well-known results predicted by the literature. The numerical results of the two models are reported and compared in terms of flow, thermal fields, and voltage drop. The results show that compressibility affects several aspects of the arc. As expected, the velocity drops when compressibility is present, however, the voltage drop increase significantly. Additionally, compressibility introduces a repetitive pattern of voltage drop over time which also depicted in the arc dynamics. The pattern is divided into three distinctive dynamics: (1) High-frequency low amplitude instabilities, followed by (2) low low-frequency high amplitude instabilities region, and finally, a relatively (3) stable interval of voltage with a bell-shaped arc.",
keywords = "Direct current, Electric arc furnace, Compressibility, Magnetohydrodynamics (MHD), Computational fluid dynamics (CFD), MHD, CFD",
author = "{Al Nasser}, Mohamad and Hadi Barati and Christian Redl and Anton Ishmurzin and Nikolaus Voller and Gernot Hackl and Manuel Leuchtenm{\"u}ller and Menghuai Wu and Abdellah Kharicha",
note = "The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. The authors acknowledge financial support from the Austrian Fed- eral Ministry of Economy, Family and Youth and the National Founda- tion for Research, Technology, and Development within the framework of the Christian-Doppler Laboratory for Metallurgical Applications of Magnetohydrodynamics.",
year = "2023",
month = jul,
day = "22",
doi = "10.1016/j.rineng.2023.101312",
language = "English",
volume = "19.2023",
journal = "Results in Engineering",
issn = "2590-1230",
publisher = "Elsevier",
number = "September",

}

RIS (suitable for import to EndNote) - Download

TY - JOUR

T1 - Effect of compressibility on industrial DC electric arcs

AU - Al Nasser, Mohamad

AU - Barati, Hadi

AU - Redl, Christian

AU - Ishmurzin, Anton

AU - Voller, Nikolaus

AU - Hackl, Gernot

AU - Leuchtenmüller, Manuel

AU - Wu, Menghuai

AU - Kharicha, Abdellah

N1 - The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper. The authors acknowledge financial support from the Austrian Fed- eral Ministry of Economy, Family and Youth and the National Founda- tion for Research, Technology, and Development within the framework of the Christian-Doppler Laboratory for Metallurgical Applications of Magnetohydrodynamics.

PY - 2023/7/22

Y1 - 2023/7/22

N2 - The paper reports on the behaviour and dynamics of direct current electric arc in an industrial electric arc furnace. Electric arcs are intense energy sources involved in many industrial processes. The behaviour of electric arc is simulated in a 2D axisymmetric geometry. A 40 kA current flows between two electrodes with a gap of 0.25 cm. The flow of current creates a very powerful jet up to km/s. Such speeds pose the question of the importance of compressibility and what is the extent of the effects of compressibility on arc behaviour. To assess the effect of compressibility, two different simulations are performed: an incompressible and a compressible simulation. The first simulation considers a temperature-dependent density based on experimental measurement whereas the latter adopts the ideal gas law to calculate the density variation of the plasma. The incompressible results were previously validated and compared to the well-known results predicted by the literature. The numerical results of the two models are reported and compared in terms of flow, thermal fields, and voltage drop. The results show that compressibility affects several aspects of the arc. As expected, the velocity drops when compressibility is present, however, the voltage drop increase significantly. Additionally, compressibility introduces a repetitive pattern of voltage drop over time which also depicted in the arc dynamics. The pattern is divided into three distinctive dynamics: (1) High-frequency low amplitude instabilities, followed by (2) low low-frequency high amplitude instabilities region, and finally, a relatively (3) stable interval of voltage with a bell-shaped arc.

AB - The paper reports on the behaviour and dynamics of direct current electric arc in an industrial electric arc furnace. Electric arcs are intense energy sources involved in many industrial processes. The behaviour of electric arc is simulated in a 2D axisymmetric geometry. A 40 kA current flows between two electrodes with a gap of 0.25 cm. The flow of current creates a very powerful jet up to km/s. Such speeds pose the question of the importance of compressibility and what is the extent of the effects of compressibility on arc behaviour. To assess the effect of compressibility, two different simulations are performed: an incompressible and a compressible simulation. The first simulation considers a temperature-dependent density based on experimental measurement whereas the latter adopts the ideal gas law to calculate the density variation of the plasma. The incompressible results were previously validated and compared to the well-known results predicted by the literature. The numerical results of the two models are reported and compared in terms of flow, thermal fields, and voltage drop. The results show that compressibility affects several aspects of the arc. As expected, the velocity drops when compressibility is present, however, the voltage drop increase significantly. Additionally, compressibility introduces a repetitive pattern of voltage drop over time which also depicted in the arc dynamics. The pattern is divided into three distinctive dynamics: (1) High-frequency low amplitude instabilities, followed by (2) low low-frequency high amplitude instabilities region, and finally, a relatively (3) stable interval of voltage with a bell-shaped arc.

KW - Direct current

KW - Electric arc furnace

KW - Compressibility

KW - Magnetohydrodynamics (MHD)

KW - Computational fluid dynamics (CFD)

KW - MHD

KW - CFD

U2 - 10.1016/j.rineng.2023.101312

DO - 10.1016/j.rineng.2023.101312

M3 - Article

VL - 19.2023

JO - Results in Engineering

JF - Results in Engineering

SN - 2590-1230

IS - September

M1 - 101312

ER -