Failure of Hot-Dip Galvanized Steel Parts : Versagen von feuerverzinkten Stahlbauteilen
Research output: Contribution to journal › Article › Research › peer-review
Authors
Organisational units
Abstract
The embrittlement of metals triggered by liquid zinc, has been known for about 140 years. William H. Johnson [1] stated that iron loses its forming capacity when dipped in melted zinc. Even today, this phenomenon still causes significant damages to hot-dip galvanized steel parts. Here, close attention should not only be paid to the composition of the molten zinc but also to the composition of the steel.
Details
Translated title of the contribution | Versagen von feuerverzinkten Stahlbauteilen |
---|---|
Original language | English |
Pages (from-to) | 641-651 |
Number of pages | 11 |
Journal | Practical metallography = Praktische Metallographie |
Volume | 53.2016 |
Issue number | 10 |
DOIs | |
Publication status | Published - Oct 2016 |